Showing posts with label QR110. Show all posts

How To Pair QR110 (MiFare) With FingerTec Master Readers




Introduction
FingerTec QR110 is a slave QR code reader for door access, and recently this model has been designed to also read MiFare card. This is a quick guide on how to pair QR110 (MiFare) with FingerTec Master Readers.

For information on QR110 (RFID) please refer to this post:
How to pair FingerTec QR110 Slave Reader with FingerTec Master Readers

QR110 (MiFare) Compatible Device -
Below are the list of FingerTec device models that are compatible with QR110 (MiFare):
1.       R2
2.       R3
3.       Q2i (FEM 800 only)
4.       Kadex
5.       M-Kadex
6.       Ingressus Controller

Note that QR110 (MiFare) is using 34-bit Wiegand signal to communicate with the master readers.

Requirement -
The main requirements needed for pairing QR110 (MiFare) with the master readers are:
1.       Wiegand-In Port
2.       Wiegand 34-bit Communication
3.       MiFare Card

Connection between QR110 and FingerTec Master Readers -
The connection for QR110 (MiFare) with the Master Readers is the same with QR110 (RFID). You may find the connection details as shown in the diagram below:

1. Pairing With Ingressus Controller
 

2. Pairing With FingerTec Master Readers.
 

QR110 MiFare Setting -
As QR110 MiFare reader is a very simple and convenient reader to begin with, no configuration or setting is required from the device. All users need to do is just plug in the device and the process is complete.

Master Readers Setting -
Before pairing the Master Readers with QR110, the devices on the other hand, will first need to be enabled in Wiegand 34-bit format as per the setting below:

1. R2 and Kadex:
Menu > option > system option > Wiegand input setting > FP device > Input format = WG34 Without ID  > Restart.

2. R3 and Q2i:
Menu > Comm > Wiegand > input option > Define = 34 > Bit counts = 34 > Input = NO. > Restart.

3. Face ID 3:
Menu > comm > Wiegand input > Wiegand Format =  Wiegand 34 > Input = Card No. > Save > Restart.

4. m-Kadex:
Requires a tool update as provided below (also works with R2 and Kadex):
https://s3.amazonaws.com/files.fingertec.com/Azim+Tools/Tools/FTEnableWG34_BWdevice.exe

 5. Ingressus:
Connect 3 Wiegand cables between QR110 (MiFare) reader and Ingressus (no other settings required).

Once done, FingerTec Master Readers will thus be paired up with the QR110 (MiFare) reader.

Note: If some of the screenshots or steps viewed here are different from the ones in the current system, this is due to our continuous effort to improve our system from time to time. Please notify us at [email protected], we will update it as soon as possible.


How To Generate QR Code In Ingress Software



Introduction -
QR110 is the latest product from FingerTec that comes with a new verification method: Scanning QR Code. This tip will show you the steps to generate the QR code in Ingress Software for access.

Process -
1. In Ingress Software, go to the Users Tab > Select Card > Select Add > and proceed to insert the Card No.
 

2. After completing the first step, please head to the Details sections and check the QR Code that was generated by the Ingress Software. Please double click at the QR Code logo (6) under the Card No. Section.
 

3. After double clicking it, the system will display a pop-up as shown below:


4. Once the QR Code has been generated, you can then save it to the PC by clicking the Save button and proceed to select folder or file destination in which you wish to save the QR Code.


5. Otherwise, you can also send it to the User’s Email by clicking on the Send Via Email button. Note: please don’t forget to insert the User’s Email Address first before proceeding.


6. Last but not least, you can even print out the QR code by clicking on the Print Button.


The output result will be as shown in the image below:



That’s it, you all done. Once received the generated QR Code, you can start to verify your employees’ identification via the latest FingerTec QR110.

How to pair FingerTec QR110 Slave Reader with FingerTec Master Readers


Introduction
QR110 QR Code Scanner is FingerTec latest product that comes with a new verification method: QR Code along with the capabilities to scan RFID/MiFare access cards as well. As a slave reader, QR110 will need to be paired with FingerTec Ingressus controllers and master readers such as R3,  R2, Q2i and etc before the whole system works.
Supported model:
Q2i, R3, R2, Face ID 3, Kadex, m-Kadex, Ingressus I/II/IV
QR110 is built with a 26-bit Wiegand communication. Even though FingerTec master devices comes with 34-bit and 26-bit Wiegand, by default all FingerTec Master Devices is set with 26-bit Wiegand Communication.

For information on QR110 (MiFare), please refer to this post:
How To Pair QR110 (MiFare) With FingerTec Master Readers

Please follow the steps below for QR110 (RFID) installation:
Process:
1) Connect the wirings between QR110 and FingerTec Controller and Biometrics Devices
  • For Ingressus I,II, and IV, please connect the respective devices to the following QR110 ports (D1, D0, GND, VCC) as shown in the circuit diagram below:   


QR 110 to Ingressus

For Master Readers (R2, R3, Kadex, m-Kadex, Q2i, Face ID 3), please connect the respective
devices to the following QR110 ports (D1, D0, GND, VCC) as shown in the circuit diagram below:




Example : R2 Connection to QR110
2) If there is no response on Master device when you wave card or scan QR code on QR110, please check the Wiegand bit Format in FingerTec Device
  • In R2 and Kadex, please go to Menu > Option > System Option > Wiegand Input Setting > FP device > Input Format = WG26 Without ID  > OK > Input = ID > OK > Restart


  • In R3 and Q2i, please go to Menu > Comm > Wiegand > Input Option > Define = 26 > Bit counts = 26 > Input = NO. > Restart
*QR110 is not compatible with Q2i (FEM 510)
  • In Face ID 3, please go to Menu > Comm > Wiegand Input > Wiegand Format =  Wiegand 26 > Input = Card No. > Save > Restart.
  • In m-Kadex, this model does not come with an interface design. Therefore, a software tool is required to enable it into a Wiegand 26-bit format. Please download the software tool here


and proceed to input the IP address of m-Kadex into the software tool. Once updated, the
m-Kadex device will now accept 26-bit Wiegand Connection. (This method can also be applied
to R2 and Kadex) Please refer to the screenshot below for more information:


  • In Ingressus I, II, and IV, the devices will automatically detect and configure its Wiegand Connection once connected to QR110. Therefore, removing the need for any manual setting.


After the configuration is done, the FingerTec devices will then be paired with QR110.