Installation Guide of Face ID 4d (FMM) With AdapTec Plus



Introduction
FingerTec Face ID 4D is now supplied with a new version of the coreboard (FMM) that comes with new hardware parts and new exterior parts. To ensure the reader connects with secured wiring, we suggest using the AdapTec Plus connection. Using AdapTec Plus can easily prevent someone from breaking into the premise.

Requirements
·         Face ID 4D
·         AdapTec Plus
·         Contactless exit button
 
Wiring diagram

Setup External Siren
Requirements

·         External siren 12VDC
·         Power Supply AdapTec Plus
·         Face ID 4D reader
·         Switch (siren mute)

Wiring diagram

-          Follow the diagram above for a wiring connection to install an external siren.
Please also make sure to connect the siren mute switch to stop the external siren.
-          If you are using a 240vac external siren. You need to add relay connect with NO/COM from the device.

 How to Setup Siren from Device
·         Go to Main Menu – Select Personalize – go to Bell Schedules – choose Options – click External Bell Relay – tick on NC2
·         Please make sure if you set Bell Schedule, don’t forget to change Repeat = ‘Never’ to the day you want to set the Schedule Bell.
 

Note: If some of the screenshots or steps viewed here are different from the ones in the current system, this is due to our continuous effort to improve our system from time to time. Please notify us at [email protected], we will update it as soon as possible.



FACE ID 5 TD / FTD Wiring for Access Control



Introduction
Good news, FingerTec has launched Face ID 5 recently, and the two new models that are equipped with temperature readers are Face ID 5 TD and Face ID 5 FTD that also can be used for building access control.

*Please state in your inquiries before purchasing the Face ID 5 with Access Push to be compatible with our software. This tip will show how the Face ID 5 can function as an access control system for in and out and   pair with our R3c device.

Process

Diagram 1 : Connection of  Face ID 5 with AdapTec Plus & R3c



Diagram 2 : Connection of  Face ID 5 with R3c 

Face ID 5 settings at the device for Access control

Picture 1 : Press Menu Icon


Picture 2 : Select COMM icon


Picture 3 : Select Serial Comm


Picture 4 : Select Serial Port


Picture 5 : Select Master Unit

After setting the Face ID 5 as a Master Unit, the IN and OUT for the device need to be set as to determine either the master will act as the IN device or OUT.


Picture 6: Push menu icon


Picture 7 : Select Access Control


Picture 8: Select the Master device and Slave device for position for ether In or Out


Picture 9 : Master Device select In or Out


Picture 10 : Slave Device select In or Out

Note: If some of the screenshots or steps viewed here are different from the ones in the current system, this is due to our continuous effort to improve our system from time to time. Please notify us at [email protected], we will update it as soon as possible.
 
  

AdapTec Plus Siren or AdapTec X Siren Remote Control Door Switch for Mute and Exit Button



Introduction
AdapTec Plus and AdapTec X has a siren function to pair with a master device to enhance the alarm sound signal from a master device. This siren will go off when a master device sends a signal such as a door open, a device broken, etc (depends on types of master) to AdapTec Plus and Adaptec X.

When using AdapTec Plus and AdapTec X siren function, please mute the siren mute function at AdapTec Plus and AdapTec X to trigger the alarm. This is how it is done using Remote control Door Switch (https://www.fingertec.com/images/w_brochure/A-R-ControlDoorSwitch_e.html), a more convenient way compared to conventional switches.

Process
FingerTec Remote Control Door Switch has two channels to mute the triggered alarm at AdapTec Plus and AdapTec X Siren and Exit Switch. Exit Switch using Remote Control Door Switch is easier for users because they can control door access remotely without needing long wiring for the exit button. Hence, receptionists can open the door for authorized people remotely.


Connection above is for internal siren for AdapTec Plus or Adaptec X only. For more sound coverage, an additional external siren 12VDC can be added. 


Note: If some of the screenshots or steps viewed here are different from the ones in the current system, this is due to our continuous effort to improve our system from time to time. Please notify us at [email protected], we will update it as soon as possible. 

Connecting the TA100C (FMM) to AdapTec TA and 12Vdc or 240Vac External Sirens

Introduction

The TA100C (FMM) is a biometric terminal for time attendance that includes an internal siren and allows the connection of external sirens for an effective alarm system. This system can also be scheduled to signal events within the working schedule such as starting work time or end of break. The two types of sirens that can be connected to the TA100C (FMM) are:

  • 12Vdc for small industries or office use
  • 240Vac for big factories with a noisy environment
To compensate for the additional power required for the external sirens, the Adaptec TA can be used as a power supply and backup in case of power failures, ensuring that your alarm system is always running.

Benefits
Connecting your terminals to the Adaptec TA ensures a stable and reliable power source for your system to operate at optimum capacity. By connecting the terminal and external siren to the Adaptec TA, the internal relay of the terminal will be protected from the high voltage. If the voltage is too high, the fuse in Adaptec will break the circuit, thus protecting the internal components of the terminal.

Adaptec TA has 2 power sources, 5VDC and 12VDC and you can connect any of FingerTec terminals to Adaptec TA by selecting the correct voltage. It also comes with a backup power in case of power failure.
 
Process
To connect the external siren to the terminal, follow the steps below.
1.    Open the back casing of the TA100C (FMM) terminal.

2.   Plug in the connector of the external siren into the MCU Board.
 
3.   Follow the wiring diagram to connect the terminal to Adaptec TA.
  
 
4.   Change the External Bell Relay settings in the terminal device itself.
      Go to Menu > Personalize > Bell Schedule > Options > External Bell Relay > NC2 

5.   To add a new bell schedule, go to Menu > Personalize > Bell Schedules > New Bell Schedule > Set
       the option accordingly:
·         Bell Status: To turn the bell on or off.
·         Bell Time: Set the time for the bell to ring automatically.
·         Repeat: Set the bell to repeat on certain days or every day.
·         Bell Type: You can set for the bell to be triggered from the internal bell or from an    
 external bell that is wired to the device.
·         Ring Tone: Select your preferred ringtone that will emit from the bell.
·         Internal Bell Relay: Specifies the time duration for the alarm to ring (ranges from 1s to999s).
·         External Bell Relay: Specifies the time duration for the alarm to ring (ranges from 1s to999s).

Tips: Cards Outputting The Same Code? Don't Forget to Configure AdapTec Correctly

If you are using AdapTec with any FingerTec terminals, the terminals will output the same Wiegand code due to AdapTec’s features. This could cause some inconveniences if you integrate the terminals with a 3rdparty controller.

 You can disable the AdapTec Plus option and revert to the normal 26-bit Wiegand output signal for a 3rdparty controller by using our FT Tool.

Click here to download the FT Tool.

For more details on the functionalities of the tool, click here.

Pairing a Door Remote Control with AdapTec Plus

With AdapTec Plus, you can unlock a door easily by using a remote control. Pair your door remote control with AdapTec Plus to use this feature.

Below is the wiring diagram showing you how to do it.

An Option to Connect an AC240V Siren with a FingerTec Device

The siren output signal from a FingerTec device is known as a dry contact and this basically means that the signal is not initially connected to a voltage source. It can also be referred to as a secondary set of contacts of a relay circuit, which does not make or break the primary current that is being controlled by the relay. Selected FingerTec devices that come with a siren include TA100C, AC100C, TimeLine 100 and other time attendance systems.

Previous installations to connect a siren with a FingerTec device could only support DC12V sirens. Now, AC240V sirens, which emits a louder sound compared to the DC12V siren, can be used in the installation provided that the relay used to control a circuit between the FingerTec device and siren supports the appropriate voltage. A power supply, such as AdapTec Plus for example, is required and must also be compatible with the relay in order for the connection to be successful.

The following installation diagram will guide you on connecting a FingerTec device to an AC240V siren with the use of a relay board and power supply.

With this in place, there is now an option provided for you to select the siren that suits your implementation better, be it a DC12V or AC240V siren.

Pairing H2i With H2i

Under certain configurations, FingerTec devices can be paired with each other in the same access control environment such as the H2i device. To pair one H2i device with another H2i device, the user needs to modify the setup for the master terminals to use it as master-slave terminals. For instructions on how to modify the setup, click here.

As a gentle reminder, please make sure that:
  • Master reader - AdapTec Plus is turned ON and the Wiegand output is User ID. 
  • Slave reader - AdapTec Plus is turned OFF and the Wiegand output is User ID. 
Please refer to the below wiring diagram for pairing two H2i devices and and AdapTec Plus:

adaptec plus, h2i, access control, fingerprint door locks, biometrics, pairing

AdapTec Plus and AdapTec-X, What’s Your Preference?

Convenience VS High-Level Security 

AdapTec Plus and AdapTec X are designed to support two installation modes; one provides utmost convenience to users and another provides high-level security but slightly compromised in terms of user experience. 

Selection of the modes is available by applying different wiring arrangements during installation. 

Under Convenient Mode, AdapTec unlocks doors immediately after receiving feedback from FingerTec devices. All FingerTec models support this feature. 

For installations using Secure Mode, there will be a 1 second delay during the unlocking of the door after verification is completed at FingerTec devices. This delay is caused by the 26-bit Wiegand transmission of encrypted data from the devices to AdapTec. 

This Secure Mode is an optional security feature provided by AdapTec for users who prefer higher level of security over user convenience. It is important to note here that the Secure Mode only delays the response of AdapTec by 1 second and it doesn’t really affect the overall user experience. Nonetheless, for users who refuse to tolerate a slight delay, Convenient Mode is highly recommended. 

Wiring Diagram for Convenient Mode Installation 



Wiring Diagram for Secure Mode Installation 


Please refer to the installer manual of AdapTec Plus and AdapTec X for more details.

FACE ID 2 IN/OUT Wiring Diagram Using AdapTec Plus

By using 2 units of Face ID 2, users can now control door access on top of checking time attendance. We will be demonstrating how to connect 2 units of the Face ID 2 terminals to work as IN/OUT terminals. You will need to connect the 2 terminals together according to the diagram below:


With the above wiring, you can now have access to enter and also exit from the same door using the 2 units of Face ID 2. Voila!

Initiated and written by: SF Lim


Comparison Between AdapTec Plus and New AdapTec Plus

The most noticeable difference between the 2 AdapTec Plus is the significant weight difference. Almost half the weight lighter compared to its predecessor, the new AdapTec Plus is able to support the NO setting for the door lock accessories such as door strikes and electromagnetic locks. It also has a brand new buzzer feature that works as an indicator every time a door is unlocked, or if there is too high a power input to the AdapTec Plus.

There are a few features that installers would find helpful as well, such as the LED light indicators. There are three LED lights in the AdapTec Plus that indicate to the user that the door lock is working, that the AdapTec processor is in good condition, and that the battery needs to be replaced.


For more information on the features of the new AdapTec Plus, click here.








Initiated by Pang
Written by Vincent

Connecting the H2i with an AdapTec Plus

With the recent release of our new product AdapTec Plus, many might wonder what is the role of AdapTec Plus in supporting the terminal. The AdapTec plus is a combination of a power supply with enhanced access control functionalities. It supports FingerTec’s encrypted 26-bit Wiegand communication output; providing enhanced security level for extra protection. With the data encryption, the life span of the terminals can be prolonged without the risk of short-circuiting. 

The H2i’s firmware has been updated to work with the AdapTec Plus. The latest firmware is available for download here

To assist our resellers further, we have prepared a simple step-by-step instruction to guide you through the setup of connecting the H2i with the AdapTec Plus.

Connecting the H2i to the AdapTec Plus
To connect the H2i to the AdapTec Plus, please refer to the below diagram. 

Updating the H2i to send an encrypted Wiegand output signal
By using the FingerTec Terminal Functions Update Tool v1.6, we can configure the H2i to send an encrypted Wiegand output signal to the AdapTec Plus.

1. Download the FingerTec Terminal Functions Update Tool v1.6 here.
2. Unzip the file and start up the FingerTec Terminal Functions Update Tool v1.6



3. Insert the IP address of the terminal and click Connect
4. When the connection is successful, the General and Access Control tab is will be accessible.



5. Click the Access Control tab and tick the checkbox for AdapTec Plus.


    6. Click Update to update the new feature into the H2i.



    7. When the update is completed, click Restart to restart the H2i.



    Your H2i will now be able to work with the AdapTec Plus. If you are still facing problems with this process, kindly contact [email protected] for further assistance.


    Initiated by: Henry Pang
    Written by:Vincent Chan

    FingerTec Terminal Function Tool V1.6

    The new FIngerTec Terminal Function Tool is now ready for download. Click here to start the download.
    The FingerTec Terminal Function Tool can be used to configure your FingerTec terminals (R2, Kadex, Q2i, iKiosk 100 and iKiosk 100 Plus) to send an encrypted Wiegand output signal so that it is able to work with the newly released AdapTec Plus. For more details about AdapTec Plus, click here.

    Before you configure your FingerTec terminals to work with the AdapTec Plus, do check the terminals’ firmware version to make sure that they are compatible with the AdapTec Plus. 
    R2: Ver 6.20 Aug 18 2011 
    Kadex:  Ver 6.20 Aug 18 2011
    Q2i [FEM 600 core board]: Ver 6.60 Sep 22 2011
    iKiosk 100 [FEM 600 core board]: Ver 6.60 Sep 22 2011
    iKiosk 100 Plus [FEM 600 core board]: Ver 6.60 Sep 22 2011
    M-kadex: Ver 6.20 Sep 23 2011
    If the existing firmware is outdated, you may download and update the relevant firmware for the terminals. 
    • For FingerTec R2 click here [date 4 Oct 2011]
    • For FingerTec Kadex click here [date 4 Oct 2011]
    • For FingerTec Q2i [FEM 600 core board] click here [date 4 Oct 2011]
    • For FingerTec iKiosk 100 [FEM 600 core board] click here [date 4 Oct 2011]
    • For FingerTec iKiosk 100 Plus  [FEM 600 core board] click here [date 4 Oct 2011]

    Configuring the Terminals

    Start up the FingerTec Terminal Function Tool v1.6 > Insert the IP address of the terminal > Click the Access Control tab > tick the “AdapTec Plus” checkbox > Select ON > Click Update > Wait for the process to be completed > Restart the terminal to allow the settings to take effect.

    You can repeat the above steps to disable the AdapTec Plus option and revert to the normal 26-bit Wiegand output signal for a 3rd party controller. 

    FingerTec Firmware Update

    New firmware to apply to Kadex, m-Kadex, R2, AC900, Q2i, TA200 Plus, i-Kiosk 100 & i-Kiosk 100 Plus to work with AdapTec Plus
    Update the new firmware of the above models to support the “encrypted 26-bit Wiegand output”. The encrypted 26-bit Wiegand output is specially developed to work with FingerTec’s AdapTec Plus. After each verification, the output for the models above encrypts codes via the 26-bit Weigand signal to the AdapTec Plus to send a door open signal for the users.
    Without this new firmware, you will not be able to use the above models with the AdapTec Plus for access control purposes.

    New features for TA100C and AC100C Webster connection
    Update the new firmware of the TA100C and AC100C, to allow the terminals to work with Webster. This is a fundamental firmware update to add the Webster connection to the mentioned models. However you will still have to contact [email protected] to request a second firmware update to activate Webster settings in your terminal.

    New features for m-Kadex
    Update the new firmware of the m-Kadex to get these 3 new features:
    -          To delete attendance logs in m-Kadex
    -          To download/upload data into USB flash disk

    Before this, an administrator can only choose to reset and clear all information in the m-Kadex. Installing the firmware in the m-Kadex, will allow you to clear attendance logs only. Now, administrators can easily clear the attendance logs in the m-Kadex to avoid a memory overflow.
    To delete attendance logs in the m-Kadex: wave administrator card 7 times at m-Kadex

    Previously, administrators can only use the USB flash disk to download attendance logs and not users. After installing the new firmware, administrator will be able to download attendance logs as well as user data into USB flash disk.
    To download attendance logs and user data into a USB flash disk: Plug USB flash disk into m-Kadex à wave administrator card 9 times at m-Kadex

    The previous firmware in the m-Kadex does not allow an administrator to upload user data into the m-Kadex via USB flash disk. An administrator can only upload user data to the m-Kadex via the TCMS V2. The new firmware fixes this flaw, and allows administrators to upload user data into m-Kadex via a USB flash disk.
    To upload user data to m-Kadex via USB flash disk: download user data into USB flash disk à Plug USB flash disk to m-Kadex à wave administrator card 11 times

    Download or view the latest m-Kadex hardware user manual guide here.